What this code means
B1036 can indicate a sustained mismatch between the body control module's IG1 input and the gauge control module's B-CAN IG1 signal.
What the vehicle may do
- The two IG1 signals can disagree for a sustained period.
Possible fault areas
- An abnormal IG1_METER reading can point to a circuit problem.
Diagnostic path
What B1036 means
On this 2025 Honda Accord 1.5, B1036 means IG1 Power supply Circuit Malfunction. The body control module compares its IG1 signal input with the IG1 signal sent by the gauge control module over B-CAN. If the signals differ for a set time or more, the body control module stores B1036. The checks focus on the external IG1_METER circuit. Here is what this code tells us. The two IG1 signals can disagree for a sustained period. Here are the main areas to check. An abnormal IG1_METER reading can point to a circuit problem.
Before troubleshooting
Before you troubleshoot, review How to Troubleshoot. If you are troubleshooting multiple DTCs, follow B-CAN System Diagnosis Test Mode A.
Separate confirmation routine
The separate Confirmation Procedure has two actions. In that routine, turn the vehicle to ON mode. Then wait for at least 6 seconds.
Scanner function reference
The diagnostic scanner (HDS) lists this function reference: Body Electrical > Lighting > Data List.
Check the IG1_METER supply
This is the separate IG1_METER circuit check. The dotted line marks the components to be tested. For this measurement, gauge control module connector A (32P) must be disconnected. With IG Mode ON, place one probe on female terminal 2 of that disconnected connector. Place the other probe on ground and measure the voltage. The reading should be 12 volt battery voltage, identified as circuit type 1. If the reading is abnormal, there is a problem in the circuit. In that case, do the additional Power Supply Inspection to locate the failure.
The code concerns disagreement between two IG1 signals, but this measurement checks the supply at a specific external circuit point. With IG Mode ON and gauge control module connector A (32P) disconnected, female terminal 2 to ground is compared with the specified 12 V battery voltage. An abnormal result identifies a circuit problem; the additional Power Supply Inspection is what locates the failure.
Power supply inspection scope
In the additional Power Supply Inspection, check every item within the dotted line for the applicable circuit type. That full area must be checked when power is not correctly supplied to a component. A blown power-supply fuse creates an open circuit. Consider causes such as a shorted wire during diagnosis. Use the circuit diagram for the circuit and terminal details. Use the separate Open/Shorted Wire Inspection methods for open or short checks. If the circuit does not match a shown type, check the circuit diagram and those open/short methods. The ◎ symbol marks a power supply input terminal.
An open power-supply path and a shorted wire are not mutually exclusive findings here: a blown supply fuse creates an open circuit, while a shorted wire remains a cause to consider. This is why the inspection covers every item within the applicable dotted-line area rather than treating the missing supply as a diagnosis of one item.
Stuck OFF condition
When the power supply input measures 0 volts instead of the normally expected voltage, use the Stuck OFF failure reference to identify possible fault areas.
Stuck ON condition
When the power supply input shows voltage instead of the expected 0 volts, use the Stuck ON failure reference to identify possible fault areas.
The expected state determines which reference applies. A 0 V reading belongs to the Stuck OFF reference only when voltage should be present; voltage belongs to the Stuck ON reference when the expected value is 0 V. These labels guide the search for possible fault areas rather than identifying a failed component by themselves.
Separate wire-check methods
The Open/Shorted Wire Inspection methods cover open wires, shorts to power supply, and shorts to ground. Each method below is a separate check. For each inspection, follow the applicable troubleshooting requirements for the specific inspection points and measurement conditions.
Open wire: resistance method
For the open-wire resistance method, disconnect the connector on every component that includes the circuit being checked. Measure the wire's resistance from connector to connector. This is resistance measurement A. The normal reading is less than 1 ohm. That means continuity.
Open wire: voltage method
The separate open-wire voltage method applies when one end of the circuit connects to power supply or reference voltage. Disconnect connector A of the component receiving that voltage. To measure voltage B, place one probe on connector terminal C, which outputs the power supply or reference voltage. Place the other probe on body ground. Then measure voltage D at connector terminal A of the receiving component. In a normal circuit, voltage B equals voltage D. If voltage B is greater than voltage D, that indicates an open circuit.
This method uses the output-side voltage B as the reference for the receiving-side voltage D, with the receiving component's connector A disconnected. The distinction is the relationship between those readings, not a separate fixed voltage target: B equals D in a normal circuit, while B greater than D indicates an open circuit. That comparison applies to the stated circuit with one end connected to power supply or reference voltage.
Short to power: resistance method
For the separate short-to-power resistance method, disconnect the connector on every component that is part of the circuit. Measure resistance A between the terminal being checked and other power lines within the same connector. The normal reading is more than 1 MΩ. That means no continuity.
Short to power: voltage method
The separate short-to-power voltage method applies to a circuit expected to be at 0 volts. Disconnect the connector on every component that is part of the circuit. To measure voltage A, place one probe at either end of the circuit and the other probe on body ground. Make voltage checks in different vehicle modes, including ON, OFF, and ACC. The normal reading is 0 volts.
Short to ground: body-ground resistance
For the separate short-to-ground resistance method, disconnect the connector on every component that is part of the circuit. Measure resistance A between the terminal being checked and body ground. The normal reading is more than 1 MΩ. That means no continuity.
Short to ground: other GND lines
Within that resistance method, also measure resistance B between the terminal being checked and other GND lines within the same connector. The normal reading is more than 1 MΩ. That means no continuity.
Short to ground: voltage method
The separate short-to-ground voltage method applies to a circuit normally carrying battery or reference voltage. Disconnect connector A of the component receiving the power supply or reference voltage. To measure voltage B, place one probe on the receiving connector terminal A. Place the other probe on body ground. Make voltage checks in different vehicle modes, including ON, OFF, and ACC. The normal reading is the power supply or reference voltage.
Final check
An abnormal IG1_METER supply reading calls for the additional Power Supply Inspection.
For more guided automotive diagnostics, visit STEP Diagnostics.