DTC guide

U0038 PF-CAN C Malfunction (BUS-OFF (Powertrain Control Module (PCM)))

U0038 can indicate that the PCM cannot send a signal to the other unit over PF-CAN C.

Vehicle Network2025 Honda Accord 1.5 turbo

Quick answer

U0038 can indicate that the PCM cannot send a signal to the other unit over PF-CAN C.

Vehicle coverage: 2025 Honda Accord 1.5 turbo. Confirm the exact configuration and applicable safety procedure before testing or repair.

On this page
  1. What this code means
  2. What the vehicle may do
  3. Possible fault areas
  4. Diagnostic path
  5. What U0038 means
  6. Before the checks
  7. Which checks apply
  8. Shared confirmation routine
  9. Check between the CAN wires
  10. Check PF-CAN C_H to ground
  11. Check PF-CAN C_L to ground
  12. Check the connected unit
  13. Check terminal 70 to ground
  14. Check terminal 56 to ground
  15. Resistance method to body ground
  16. Resistance method to other ground lines
  17. Separate voltage-check method
  18. U0038 troubleshooting direction
  19. U0038 confirmation routine
  20. Listed scanner function
  21. More diagnostic steps
  22. Final check
U0038 PF-CAN C Malfunction (BUS-OFF (Powertrain Control Module (PCM))) diagnostic guide

What this code means

U0038 can indicate that the PCM cannot send a signal to the other unit over PF-CAN C.

The code describes the communication failure detected by the PCM, rather than identifying which part failed. That is why the U0038 diagnostic path separates the external wiring inspection from the connected-unit inspection.

What the vehicle may do

  • The PCM may be unable to send a signal over PF-CAN C.
  • The PCM can store U0038 when that communication fails.

Possible fault areas

  • The PF-CAN C wiring may have a short.
  • A connected unit may have an internal short.
  • The PCM may have a problem.

Diagnostic path

What U0038 means

Perform the following inspections based on the DTC stored in each unit. DTC Inspection Items Work Items • Electric Brake Booster: VF-CAN L_H/VF-CAN B_H, VF-CAN L_L/VF-CAN B_L Shorted Wire External Circuit U0047-00 Inspection • Electric Brake Booster: VF-CAN L/VF-CAN B Connected Unit VF-CAN L/VF-CAN B Connected Unit Inspection U0047-00 • PCM: U0038 External Circuit PF-CAN C_H, PF-CAN C_L Shorted Wire Inspection • TCM: U0038 • PCM: U0038 PF-CAN C Connected Unit PF-CAN C Connected Unit Inspection • TCM: U0038

On this 2025 Honda Accord 1.5, U0038 means PF-CAN C Malfunction, BUS-OFF, in the Powertrain Control Module (PCM). The PCM stores this code when it cannot send a signal to the other unit over PF-CAN C. Possible fault areas include shorted wiring, an internal short in a connected unit, or a PCM problem. Here is what this code tells us. The PCM may be unable to send a signal over PF-CAN C. The PCM can store U0038 when that communication fails. Here are the main areas to check. The PF-CAN C wiring may have a short. A connected unit may have an internal short. The PCM may have a problem.

Before the checks

Troubleshoot any DTCs listed or indicated systems below first. - Network Communications \[CAN gateway\]: Go to the indicated DTC's troubleshooting

Before you troubleshoot, review How to Troubleshoot. This BUS-OFF check covers the F-CAN circuit that is not connected to the CAN gateway. If the failure happens intermittently or is difficult to reproduce, review How to Troubleshoot (Handling Intermittent and Low Reproducibility Failures). First, troubleshoot any indicated Network Communications \[CAN gateway\] DTCs using the troubleshooting for those codes.

Which checks apply

Use the inspections assigned to the DTC stored in each unit. For Electric Brake Booster: U0047-00, the external-circuit check is VF-CAN L_H/VF-CAN B_H, VF-CAN L_L/VF-CAN B_L Shorted Wire Inspection. The connected-unit check is VF-CAN L/VF-CAN B Connected Unit Inspection. For PCM: U0038 or TCM: U0038, the external-circuit check is PF-CAN C_H, PF-CAN C_L Shorted Wire Inspection. The connected-unit check is PF-CAN C Connected Unit Inspection.

Shared confirmation routine

The shared confirmation routine is defined separately from the wiring checks. It specifies turning the vehicle to the ON mode. For the details, check the Confirmation Procedure for the DTC being checked.

Check between the CAN wires

Let us look at the separate PF-CAN C_H, PF-CAN C_L Shorted Wire Inspection. Before you disconnect the PCM connector and the TCM connector, jump the SCS line with the diagnostic scanner (HDS). Wait more than 1 minute. For this check, PCM connector A (72P) and TCM connector (50P) must be disconnected. Use the specified inspection points and conditions. With IG Mode OFF, measure resistance at disconnected PCM connector A (72P). Place one probe on female terminal 70 and the other probe on female terminal 56. The reading should be more than 1 megaohm. That is normal for this wire-to-wire check.

Check PF-CAN C_H to ground

For the following shorted-circuit checks, use the Open/Shorted Wire Inspection Description method, then check according to the circumstances. With PCM connector A (72P) disconnected and IG Mode OFF, measure resistance to ground. Place one probe on female terminal 70 and the other probe on ground. The reading should be more than 1 megaohm. That is normal for PF-CAN C_H to ground.

Check PF-CAN C_L to ground

With PCM connector A (72P) disconnected and IG Mode OFF, measure resistance to ground. Place one probe on female terminal 56 and the other probe on ground. The reading should be more than 1 megaohm. That is normal for PF-CAN C_L to ground. If a result in these external-circuit checks is abnormal, there is a problem in the circuit.

These three measurements check different short-circuit paths: between PF-CAN C_H and PF-CAN C_L, from C_H to ground, and from C_L to ground. A normal wire-to-wire reading does not establish that either wire passes its ground check. With PCM connector A (72P) and TCM connector (50P) disconnected and IG Mode OFF, each specified measurement must be more than 1 MΩ; an abnormal external-circuit result points to a circuit problem.

Check the connected unit

Now, here is the separate PF-CAN C Connected Unit Inspection. Before disconnecting the PCM connector and the TCM connector, jump the SCS line with the scanner. Wait more than 1 minute. This connected-unit procedure can be done before any other inspections are completed because it includes all the following inspection items. However, if this test fails, continue with each inspection item individually to determine which item failed. This inspection requires the external circuit to be normal. Its preparation requires PCM connector A (72P) and TCM connector (50P) disconnected. Reconnect the listed connectors one by one and check as specified. The connector listed here is TCM connector (50P). With PCM connector A (72P) still disconnected and IG Mode OFF, check between its female terminals 70 and 56. The expected result is not shorted.

Check terminal 70 to ground

For the next connected-unit check, PCM connector A (72P) must remain disconnected, with IG Mode OFF. Check its female terminal 70 to ground. The expected result is not shorted.

Check terminal 56 to ground

With PCM connector A (72P) disconnected and IG Mode OFF, check its female terminal 56 to ground. The expected result is not shorted. If the connected-unit inspection is abnormal, the unit whose connector was connected has a shorted circuit. If the connected-unit inspection is normal, there is a problem with the PCM.

The normal-external-circuit prerequisite is what makes the connected-unit result meaningful. With that prerequisite met, an abnormal result after reconnecting TCM connector (50P) identifies a shorted circuit in the connected unit, while a normal connected-unit inspection points to a PCM problem. Although the combined procedure may be performed first, a failed combined test still requires the individual inspection items to distinguish which item failed.

Resistance method to body ground

Here is the separate short-to-ground resistance method used by the circuit checks. Follow the specific inspection points and measurement conditions for the troubleshooting you are doing. Disconnect the connector on each component that is part of the circuit being checked. Measure resistance between the connector terminal being checked and body ground. The normal reading is more than 1 MΩ, with no continuity.

Resistance method to other ground lines

In that resistance method, also measure between the terminal being checked and other GND lines within the same connector. The normal reading is more than 1 MΩ, with no continuity.

Separate voltage-check method

A separate method uses battery or reference voltage on a circuit presumed normal to check for a short to body ground. Follow the specific inspection points and measurement conditions for the troubleshooting you are doing. Voltage checks should be done in different vehicle modes, including ON, OFF, and ACC. Disconnect the connector of the component receiving the power supply or reference voltage. Measure voltage with one probe on that receiving connector terminal and the other probe on body ground. The normal result is the power supply or reference voltage.

U0038 troubleshooting direction

For U0038, use the troubleshooting for F-CAN BUS OFF (CAN BUS without Connection to CAN Gateway).

U0038 confirmation routine

The separate U0038 Confirmation Procedure specifies this action: turn the vehicle to the ON mode, and wait 6 seconds.

Listed scanner function

The listed HDS function is PGM-FI > Data List.

More diagnostic steps

For more diagnostic steps, visit stepdiagnostics.com.

Final check

The checks can identify an external-circuit problem, a connected-unit short, or a PCM problem.

For more guided automotive diagnostics, visit STEP Diagnostics.