DTC guide

U01B0 PGM-FI - 12 Volt Battery Sensor LIN Communication Error

U01B0 can indicate lost LIN communication between the PCM and the battery sensor.

Vehicle Network2025 Honda Accord 1.5 turbo

Quick answer

U01B0 can indicate lost LIN communication between the PCM and the battery sensor.

Vehicle coverage: 2025 Honda Accord 1.5 turbo. Confirm the exact configuration and applicable safety procedure before testing or repair.

On this page
  1. What this code means
  2. What the vehicle may do
  3. Possible fault areas
  4. Diagnostic path
  5. What U01B0 means
  6. Before troubleshooting
  7. Choose the applicable checks
  8. Confirmation routine
  9. Prepare the power and LIN circuit check
  10. Path A: battery sensor power
  11. Paths A and B: LIN continuity
  12. Path A: LIN short to ground
  13. If the power reading is abnormal
  14. Path A: connected components
  15. Path B: battery sensor check
  16. Path A: battery sensor circuit
  17. Path A: PCM conclusion
  18. Conditions for the wire-check methods
  19. Open wire: resistance method
  20. Open wire: voltage comparison
  21. Short to power: resistance method
  22. Short to power: voltage method
  23. Short to ground: body-ground resistance
  24. Short to ground: other ground lines
  25. Short to ground: voltage method
  26. Power supply checks
  27. Stuck OFF and stuck ON references
  28. Final check
U01B0 PGM-FI - 12 Volt Battery Sensor LIN Communication Error diagnostic guide

What this code means

U01B0 can indicate lost LIN communication between the PCM and the battery sensor.

What the vehicle may do

  • The PCM may store U01B0 when sensor signals cannot arrive via LIN.

Possible fault areas

  • Loose sensor terminals or faults in power and LIN wiring may be involved.
  • The alternator, shutter grille, or DC-DC converter may be involved.
  • The battery sensor or PCM may also be involved.

Diagnostic path

What U01B0 means

On this 2025 Honda Accord 1.5, U01B0 means PGM-FI - 12 Volt Battery Sensor LIN Communication Error. The PCM can store this code when it cannot receive the battery sensor signals through LIN. Possible fault areas include the sensor connections, wiring, connected components, and PCM. Here is what this code tells us. The PCM may store U01B0 when sensor signals cannot arrive via LIN. Here are the main areas to check. Loose sensor terminals or faults in power and LIN wiring may be involved. The alternator, shutter grille, or DC-DC converter may be involved. The battery sensor or PCM may also be involved.

Before troubleshooting

Before you troubleshoot, review How to Troubleshoot. Then check for loose terminals on the battery sensor at the 12 volt battery negative (-) terminal.

Choose the applicable checks

The dotted line in the inspection outline identifies the components to be tested. Depending on the failure and vehicle conditions, some inspection items may be ruled out. Check whether DTC P16E2 is indicated. If it is, use path A. That path includes the +B_STOP, LIN(BATT_SENSOR) circuit check, the connected-component check, the battery sensor circuit check, and the PCM check. If P16E2 is not indicated, use path B. That path includes the +B_STOP, LIN(BATT_SENSOR) circuit check and the battery sensor check.

P16E2 selects the inspection path; it does not by itself identify a failed part. Both paths include the +B_STOP, LIN(BATT_SENSOR) Circuit Inspection, but they use different battery sensor checks. Path A uses the battery sensor circuit check and includes a PCM conclusion, while path B uses the separate battery sensor inspection.

Confirmation routine

Here is the confirmation routine that the battery sensor check calls for later. When that routine is called, turn the vehicle to ON mode. Wait 60 seconds.

Prepare the power and LIN circuit check

The diagnostic scanner (HDS) function listing is PGM-FI > Data List. For the +B_STOP, LIN(BATT_SENSOR) Circuit Inspection, jump the SCS line with the scanner before disconnecting the PCM connector. Wait more than 1 minute before disconnecting it. For the circuit measurements, the 12 volt battery sensor connector (3P), PCM connector A (72P), and Alternator connector (1P) must be disconnected. With a shutter grille, disconnect the Shutter grille connector (4P). With the auto idle stop system, disconnect DC-DC converter connector A (3P). Then make the applicable circuit checks that follow.

Path A: battery sensor power

This +B_STOP check applies to path A. IG Mode must be OFF, and the 12 volt battery sensor connector (3P) must be disconnected. To measure voltage, place one probe on 12 volt battery sensor connector terminal 2 and the other probe on ground. The normal reading is 12 volt battery voltage, circuit type 1. If the result is abnormal, there is a problem in the circuit.

Paths A and B: LIN continuity

The LIN(BATT_SENSOR) open-wire check applies to both paths A and B. IG Mode must be OFF, with the circuit-check connectors disconnected as specified. To measure resistance, place one probe on 12 volt battery sensor connector terminal 3. Place the other probe on PCM connector A (72P) terminal 57. The reading should be less than 1 ohm. If the result is abnormal, there is a problem in the circuit.

Path A: LIN short to ground

For this short-circuit check, use the shorted-wire inspection method according to the circumstances. This LIN(BATT_SENSOR) check applies to path A. IG Mode must be OFF, with the circuit-check connectors disconnected as specified. To measure resistance, place one probe on 12 volt battery sensor connector terminal 3 and the other probe on ground. The reading should be more than 1 megaohm. If the result is abnormal, there is a problem in the circuit.

These two resistance checks answer different questions. With IG Mode OFF and the specified connectors disconnected, less than 1 ohm between battery sensor terminal 3 and PCM connector A (72P) terminal 57 establishes continuity between those points. More than 1 megaohm from battery sensor terminal 3 to ground establishes no continuity to ground. A normal end-to-end reading therefore does not replace the separate path A short-to-ground check.

If the power reading is abnormal

If the power supply check gave an abnormal result, do the additional Power Supply Inspection to locate the failure.

Path A: connected components

For path A, the Components Connected to LIN(BATT_SENSOR) \[LIN\] Circuit Inspection requires a normal external circuit. Before disconnecting the PCM connector, jump the SCS line with the scanner. Wait more than 1 minute before disconnecting it. This check can be done before the other inspections are completed because it includes the following inspection items. If it fails, each inspection item must still be checked individually to identify which one failed. Prepare with the 12 volt battery sensor connector (3P), Alternator connector (1P), and PCM connector A (72P) disconnected. With a shutter grille, disconnect the Shutter grille connector (4P). With the auto idle stop system, disconnect DC-DC converter connector A (3P). For the measurement, IG Mode must be OFF. Keep the 12 volt battery sensor connector (3P) disconnected. Check its terminal 3 to ground while reconnecting the other connectors one at a time. Start with the Alternator connector (1P). Then reconnect the Shutter grille connector (4P), if equipped. Then reconnect DC-DC converter connector A (3P), with the auto idle stop system. Finally, reconnect PCM connector A (72P). The normal condition is not shorted. If reconnecting a part produces a short, replace the part that shorted when reconnected.

Reconnecting the listed connectors one at a time ties the appearance of a short to a particular reconnection. With the external circuit normal, IG Mode OFF, and the battery sensor connector (3P) still disconnected, the result at terminal 3 to ground identifies the part that shorts when reconnected. That change—not simply the presence of a part on the LIN circuit—is the basis for the stated replacement decision.

Path B: battery sensor check

For path B, the battery sensor check requires a normal external circuit. This check works through related components rather than directly testing the sensor itself. Now perform the confirmation routine: turn the vehicle to ON mode and wait 60 seconds. Then check whether DTC P16E2 is indicated. The normal condition is that P16E2 is not indicated. With that normal result, there is a problem with the battery sensor. If P16E2 is indicated, the result is abnormal, and there is a problem with other related components.

Here, “normal” describes the P16E2 result, not the health of the battery sensor. This is an indirect inspection with a normal external circuit as its prerequisite. After the ON-mode confirmation and 60-second wait, no P16E2 points to the battery sensor; P16E2 being indicated points to other related components.

Path A: battery sensor circuit

For path A, the separate battery sensor circuit check requires a normal external circuit. Before disconnecting the PCM connector, jump the SCS line with the scanner. Wait more than 1 minute before disconnecting it. This check can be done before the other inspections are completed because it includes the following inspection items. If it fails, check each inspection item individually to identify which one failed. Prepare with the Alternator connector (1P) and PCM connector A (72P) disconnected. With a shutter grille, disconnect the Shutter grille connector (4P). With the auto idle stop system, disconnect DC-DC converter connector A (3P). For the sensor internal circuit check, IG Mode must be OFF. Keep the Alternator connector (1P) disconnected. Check alternator connector terminal 1 to ground. The normal condition is not shorted. An abnormal result means there is a problem with the battery sensor.

Path A: PCM conclusion

If all the other applicable inspection items show normal conditions, the remaining cause is the PCM.

The path A PCM conclusion depends on eliminating the other applicable inspection items through normal results. It is not a conclusion drawn from U01B0 alone, nor from one normal circuit measurement.

Conditions for the wire-check methods

The following are separate wire-check methods. Use them as applicable to the circuit checks. Follow the specific inspection points and measurement conditions required by the troubleshooting check you are doing.

Open wire: resistance method

For the open-wire resistance method, disconnect the connector on each component that includes the circuit being checked. Measure the wire resistance from connector to connector. The reading should be less than 1 ohm. That means continuity.

Open wire: voltage comparison

The separate open-wire voltage method applies when one end connects to a power supply or reference voltage. Disconnect the connector of the component receiving that voltage. To measure the supplying-end voltage, place one probe on the terminal supplying the power or reference voltage. Place the other probe on body ground. Then measure voltage at the connector terminal of the component receiving that voltage. In a normal circuit, the supplying-end and receiving-end voltages are equal. If the supplying-end voltage is greater than the receiving-end voltage, that is an open-circuit result.

Short to power: resistance method

For the separate short-to-power resistance method, disconnect the connector on every component in the circuit being checked. Measure resistance between the terminal being checked and other power lines within the same connector. The normal reading is more than 1 MΩ. That means no continuity.

Short to power: voltage method

The separate short-to-power voltage method applies to a circuit expected to be at 0 volts. Disconnect the connector on every component in the circuit being checked. Make voltage checks in different vehicle modes, including ON, OFF, and ACC. To measure voltage, place one probe at either end of the circuit and the other probe on body ground. The reading should be 0 volts.

Short to ground: body-ground resistance

For the separate short-to-ground resistance method, disconnect the connector on every component in the circuit being checked. Measure resistance between the terminal being checked and body ground. The normal reading is more than 1 MΩ. That means no continuity.

Short to ground: other ground lines

With the connectors still disconnected for this resistance method, measure resistance to the other GND lines within the same connector. Measure from the terminal being checked. The normal reading is more than 1 MΩ. That means no continuity.

Short to ground: voltage method

The separate short-to-body-ground voltage method applies to a circuit expected to have battery or reference voltage. Disconnect the connector of the component receiving the power supply or reference voltage. Make voltage checks in different vehicle modes, including ON, OFF, and ACC. To measure voltage, place one probe on the receiving connector terminal and the other probe on body ground. The reading should be the power supply or reference voltage.

Power supply checks

The separate Power Supply Inspection applies when power is not correctly supplied to a component. Check all items within the dotted line for the applicable circuit type. The ◎ symbol identifies the power supply input terminal. A blown power supply fuse creates an open circuit. During diagnosis, consider causes such as a shorted wire. Use the open- and shorted-wire inspection methods for those checks. Use the circuit diagram for the circuit and terminal details. If the circuit does not match a shown type, check the circuit diagram and the open- and shorted-wire inspection methods.

Stuck OFF and stuck ON references

If the power supply input reads 0 volts instead of the expected voltage, use the Stuck OFF reference to identify possible fault areas. If the input shows voltage instead of the expected 0 volts, use the separate Stuck ON reference.

Final check

The P16E2 result can determine which U01B0 inspection path applies.

For more guided automotive diagnostics, visit STEP Diagnostics.