What this code means
U0298 can indicate that the PCM is not receiving DC-DC converter signals through LIN.
What the vehicle may do
- The PCM may not receive DC-DC converter signals through LIN.
- The PCM can store U0298 when those signals are not received.
Possible fault areas
- Possible faults include the IG1_ACG and LIN(BATT_SENSOR) circuits.
- A component connected to LIN(BATT_SENSOR) may have an internal short.
- The DC-DC converter or PCM may be at fault.
Diagnostic path
Understanding U0298
On this 2025 Honda Accord 1.5, U0298 means PGM-FI - DC-DC LIN Communication Error. The PCM stores this code when it cannot receive the DC-DC converter signals through LIN. Possible fault areas include the wiring, components connected to LIN, the converter, and the PCM. Here is what this code tells us. The PCM may not receive DC-DC converter signals through LIN. The PCM can store U0298 when those signals are not received. Here are the main areas to check. Possible faults include the IG1_ACG and LIN(BATT_SENSOR) circuits. A component connected to LIN(BATT_SENSOR) may have an internal short. The DC-DC converter or PCM may be at fault.
Before troubleshooting
Before you troubleshoot, review How to Troubleshoot.
Confirmation procedure
Here is the separate confirmation procedure used when a check calls for it. Turn the vehicle to the ON mode. Wait 10 seconds.
Choosing the applicable checks
Is DTC P16E2 indicated? If yes, use path A. If no, use path B. Both paths include the IG1_ACG, LIN(BATT_SENSOR) Circuit Inspection. Path A also includes the Component Connected to LIN(BATT_SENSOR) \[LIN\] Circuit Inspection, DC-DC Converter Circuit Inspection, and PCM Inspection. Path B includes the DC-DC Converter Inspection. The dotted line marks the components to be tested. Depending on the failure conditions and the vehicle, some inspection items may be eliminated as potential failures.
Scanner reference
The listed function path for the diagnostic scanner (HDS) is PGM-FI > Data List.
IG1_ACG power supply
For the IG1_ACG, LIN(BATT_SENSOR) Circuit Inspection, jump the SCS line with the scanner before disconnecting the PCM connector. Wait more than 1 minute. Disconnect DC-DC converter connector A (3P) and PCM connector A (72P). Disconnect Alternator connector (1P) and 12 volt battery sensor connector (3P). With a shutter grille, also disconnect Shutter grille connector (4P). Use the applicable checks that follow. The IG1_ACG voltage check applies to path B. Keep DC-DC converter connector A (3P) disconnected. With IG Mode ON, place one probe on female terminal 3 and the other probe on body ground. Measure the voltage. The normal reading is 12 volt battery voltage, circuit type 1. An abnormal result means there is a problem in the circuit. If this power supply check is abnormal, do the additional Power Supply Inspection to locate the failure.
This path B check evaluates the IG1_ACG supply at the disconnected converter connector, not the converter itself. An abnormal voltage result identifies a circuit problem; the additional Power Supply Inspection is what narrows down that supply failure.
LIN wire continuity
The separate LIN(BATT_SENSOR) open wire check applies to paths A and B. For this resistance check, IG Mode must be OFF. DC-DC converter connector A (3P) and PCM connector A (72P) must be disconnected. Use the female terminals. Place one probe on DC-DC converter connector A terminal 1. Place the other probe on PCM connector A terminal 57. Measure the resistance. The normal reading is less than 1 ohm. An abnormal result means there is a problem in the circuit.
LIN short to ground
The separate LIN(BATT_SENSOR) shorted to ground check applies to path A. Use the Open/Shorted Wire Inspection Description method for this shorted-circuit check, according to the circumstances. For this resistance check, IG Mode must be OFF and DC-DC converter connector A (3P) must be disconnected. Place one probe on female terminal 1 and the other probe on body ground. Measure the resistance. The normal reading is more than 1 megohm. An abnormal result means there is a problem in the circuit.
The two LIN resistance checks answer different questions. Less than 1 ohm between the specified converter and PCM terminals establishes continuity along the wire. More than 1 megohm from the specified converter terminal to body ground establishes no continuity to ground. A normal open-wire result therefore does not replace path A's separate short-to-ground check.
Components connected to LIN
Path A includes a separate Component Connected to LIN(BATT_SENSOR) \[LIN\] Circuit Inspection. The external circuit must be normal. This test can be done before the other inspections because it includes their inspection items. If it fails, check each inspection item individually to find which item failed. Before disconnecting the PCM connector, jump the SCS line with the scanner. Wait more than 1 minute. Disconnect DC-DC converter connector A (3P), Alternator connector (1P), and 12 volt battery sensor connector (3P). With a shutter grille, disconnect Shutter grille connector (4P). Disconnect PCM connector A (72P). For the resistance measurement, IG Mode must be OFF. Keep DC-DC converter connector A (3P) disconnected. Measure between its female terminal 1 and body ground while reconnecting the listed connectors one at a time. Reconnect Alternator connector (1P), then 12 volt battery sensor connector (3P). With a shutter grille, reconnect Shutter grille connector (4P). Then reconnect PCM connector A (72P). The normal condition is not shorted. If the result is abnormal, the problem is with the part that caused the short when reconnected.
Reconnecting one connector at a time ties the appearance of a short to a particular reconnection. With the external circuit normal, the stated abnormal conclusion applies to the part whose reconnection caused the short, rather than to every component connected to LIN.
DC-DC converter DTC check
Path B includes the separate DC-DC Converter Inspection. The external circuit must be normal. This check evaluates related components rather than directly testing the converter itself. Perform the confirmation procedure described earlier: turn the vehicle to the ON mode and wait 10 seconds. The normal result is that DTC P16E2 is not indicated. If that result is normal, there is a problem with the DC-DC converter. If P16E2 is indicated, the result is abnormal, and there is a problem with other related components.
Here, “normal” describes the P16E2 check result, not the health of the converter. Because this inspection evaluates related components indirectly and requires a normal external circuit, P16E2 not being indicated leads to the converter conclusion. P16E2 being indicated instead points to other related components.
DC-DC converter circuit
Path A includes the separate DC-DC Converter Circuit Inspection. The external circuit must be normal. This test can be done before the other inspections because it includes their inspection items. If it fails, check each inspection item individually to find which item failed. Before disconnecting the PCM connector, jump the SCS line with the scanner. Wait more than 1 minute. Disconnect Alternator connector (1P) and 12 volt battery sensor connector (3P). With a shutter grille, disconnect Shutter grille connector (4P). Disconnect PCM connector A (72P). For this internal circuit check, IG Mode must be OFF. Keep Alternator connector (1P) disconnected. Measure resistance between its female terminal 1 and body ground. The normal condition is not shorted. If the result is abnormal, there is a problem with the DC-DC converter.
Conditional PCM conclusion
The PCM Inspection applies to path A. If all the other inspection items show normal conditions, the remaining PCM is determined to be the cause. This conclusion depends on the other inspection results being normal.
The PCM conclusion is reached by elimination within path A, not from the communication code alone. The code establishes that the PCM did not receive the converter signals; the normal results from the other inspection items are what support identifying the remaining PCM as the cause.
Open wire resistance method
These are separate wire-check methods to use when the applicable troubleshooting calls for them. Use the specific inspection points and measurement conditions for the circuit you are checking. For an open wire continuity check, disconnect the connector on each component that includes that circuit. Measure the wire's resistance, marked A, from connector to connector. The normal reading is less than 1 ohm. That indicates continuity.
Open wire voltage method
The voltage difference check is a separate method for checking an open wire. It applies when one end of the circuit is connected to a power supply or reference voltage. Disconnect connector A on the component receiving that voltage. To measure voltage B, place one probe on connector terminal C, which outputs the power supply or reference voltage. Place the other probe on body ground.
Comparing the voltages
Next, measure voltage D at connector terminal A on the component receiving the power supply or reference voltage. Normally, voltage B equals voltage D. If voltage B is greater than voltage D, the result indicates an open circuit.
Short to power resistance method
The resistance check for a short to power is another separate method. Disconnect the connector on each component that is part of the circuit being checked. Measure resistance A between the terminal being checked and other power lines within the same connector. The normal reading is more than 1 MΩ. That means no continuity.
Short to power voltage method
The separate voltage check for a short to power applies to a circuit normally expected to read 0 volts. Disconnect the connector on each component that is part of the circuit you are checking. Measure voltage A to body ground at either end of the circuit. Do the voltage checks in different vehicle modes, including ON, OFF, and ACC. The normal reading is 0 volts.
Resistance to body ground
The resistance check for a short to ground is a separate method. Disconnect the connector on each component that is part of the circuit being checked. Measure resistance A between the terminal being checked and body ground. The normal reading is more than 1 MΩ. That means no continuity.
Resistance to other ground lines
For the other resistance measurement in this method, measure resistance B to other GND lines within the same connector. Measure from the connector terminal being checked. The normal reading is more than 1 MΩ. That means no continuity.
Short to ground voltage method
The separate voltage check for a short to body ground applies to a circuit normally carrying battery or reference voltage. Disconnect connector A on the component receiving the power supply or reference voltage. To measure voltage B, place one probe on receiving connector terminal A and the other probe on body ground. Do the voltage checks in different vehicle modes, including ON, OFF, and ACC. The normal reading is the power supply or reference voltage.
Power supply fault checks
The additional Power Supply Inspection applies when power is not correctly supplied to a component. Check all items within the dotted line for the applicable circuit type. A blown power supply fuse creates an open circuit. During diagnosis, consider causes such as a shorted wire. Use the Open/Shorted Wire Inspection Description methods for open or short circuit checks. Use the circuit diagram for the circuit and terminal details. If the circuit does not match a shown type, check the circuit diagram and those open or short circuit methods. The double-circle symbol marks the power supply input terminal.
Stuck OFF and stuck ON
If the power supply input reads 0 volts instead of the expected voltage, use the Stuck OFF Failure table for possible fault areas. If the input shows voltage instead of the expected 0 volts, use the Stuck ON Failure table for possible fault areas.
Final check
The documented checks can separate circuit faults, connected-component shorts, and conditional converter or PCM faults.